K6 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF) |
Type | K6-500A | K6-1000A | K6-1500A | K6-2000A | K6-3000A | Unit |
Rated current(Ipn) | ±500 | ±1000 | ±1500 | ±2000 | ±3000 | A |
Measure range(Ip) | 0-±1000 | 0-±2000 | 0-±2250 | 0-±3000 | 0-±4000 | A |
Rated output | @Ip=±Ipn ±4±1% | V | ||||
Supply voltage | ±12,±15 | V | ||||
Power Consumption | <25 | mA | ||||
Offset voltage | @Ip=0 ±20 | mV | ||||
Magnetic offset | @Ip=±Ipn-0 ±20 | mV | ||||
Offset drift | @ -40~+85ºC ≤±1 | mV/ºC | ||||
Output drift | @ -40~+85ºC ≤±1 | mV/ºC | ||||
Linearity | @Ip=0-±Ipn ≤1 | %FS | ||||
Response time | @50A/μS, 10%-90% ≤7 | μs | ||||
Galvanic isolation | @ 50HZ,AC,1min 6 | KV | ||||
Isolation resistance | @ DC 500V 1000 | MΩ |
Applications |
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V
Directions for use |
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.
Standards |
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
General date |
Value | Unit | |
Operating temperature(TA) | -40 to +85 | ºC |
Storage temperature(TS) | -40 to +125 | ºC |
Mass(approx) (M) | 580 | g |